National Monitoring
Network
Nitrate Methods/Data
Please return to:
Jerry Diamond, Tetra Tech,
Inc.
410-356-9005 (fax)
jerry.diamond@tetratech.com
Organization:
Contact
Name: Stephen
Wolcott swolcott@usgs.gov 518-285-5676
Michael
McHale mmchale@usgs.gov 518-285-5675
Tricia
Lincoln tarenga@usgs.gov 518-285-5612
Sample Collection |
||||
|
|
|
Comments
|
||
|
Container
type |
glass x
plastic other |
|
||
|
Preservation
method |
acid mercuric chloride freeze x other |
Refrigeration |
||
|
Sampling
method available to public? |
x
Yes No |
|
||
|
Sample
Processing and Analysis |
||||
|
Sample
holding time |
14
|
|
||
|
Sample
filtration |
x
filtered
unfiltered |
If
filtered – filter type and mesh size 0.4 µm
polycarbonate |
||
|
Laboratory
analysis method available to the public? |
x
Yes No |
|
||
|
Analysis
method used |
http://ny.water.usgs.gov/pubs/of/of95416/ |
Any
modifications used? |
||
|
Method
detection limit (if known) |
|
Reporting limit |
||
QA/QC
|
||||
Replicate
samples collected?`
|
x
Yes No
|
Frequency
1
triplicate set per 50 samples
|
||
Matrix
spike/ matrix spike duplicates performed?
|
Yes x No
|
Frequency
|
||
Check
or reference sample analyzed?
|
x Yes
No
|
Frequency 1 set of 2 QC’s
every ten samples
|
||
|
x
Yes No
|
Frequency
http://ny.water.usgs.gov/pubs/of/of96167/ http://ny.water.usgs.gov/pubs/of/of01071/ other QA/QC reports
are in progress |
||
|
||||
|
Sample
Location info: x
Yes
No Sample
collection date: x Yes No Reason
for sampling: Yes x No How
samples collected: x
Yes
No How
samples analyzed: x
Yes
No FGDC1
metadata: Yes No QA/QC
info: x Yes No |
??????????????? |
||
How
are metadata available?
|
x
Internet CD x Upon
request x other |
|
||
Data Reporting
|
||||
Final
form of data
|
x
hardcopy tables x electronic
tables other |
http://pubs.usgs.gov/wdr/wdr-ny-03-1/
|
||
Are
data publicly available?
|
x
Yes No |
On the Internet?
Yes_x__
No___
|
||
Are
ancillary data available for samples?
|
x temperature
salinity/x conductivity
dissolved oxygen x hydrology/flow x others |
|
||
1 = Federal Geographic Data Committee http://www.fgdc.gov/metadata/
National Monitoring
Network
Nitrate Methods/Data
Please return to:
Jerry Diamond, Tetra Tech,
Inc.
410-356-9005 (fax)
jerry.diamond@tetratech.com
Organization:
PA DEP – Bureau of Laboratoires
Contact
Name: Ted Lyter
Contact
Phone # and email: 717-346-8294 plyter@state.pa.us
Sample Collection |
||||
|
|
|
Comments
|
||
|
Container
type |
plastic |
|
||
|
Preservation
method |
other |
4
degree-c or below |
||
|
Sampling
method available to public? |
Yes |
|
||
|
Sample
Processing and Analysis |
||||
|
Sample
holding time |
2
|
We
use 48 hours as the upper limit |
||
|
Sample
filtration |
unfiltered |
If
filtered – filter type and mesh size |
||
|
Laboratory
analysis method available to the public? |
Yes |
Standard
EPA method – see below |
||
|
Analysis
method used |
EPA
353.2 |
Any
modifications used? No |
||
|
Method
detection limit (if known) |
0.017 mg/L
|
Reporting
limit is 0.04 mg/L |
||
QA/QC
|
||||
Replicate
samples collected?`
|
Yes Not on routine basis No
|
Frequency
One in ten |
||
Matrix
spike/ matrix spike duplicates performed?
|
No
|
Frequency
|
||
Check
or reference sample analyzed?
|
Yes
No ??????????
|
Frequency
|
||
|
Yes No ??????????
|
Frequency
|
||
|
||||
|
Sample
Location info: Yes Sample
collection date: Yes Reason
for sampling: Yes How
samples collected: Yes How
samples analyzed: Yes FGDC1
metadata: Yes No???? QA/QC
info: Yes No????? |
|
||
How
are metadata available?
|
Internet CD Upon request other |
|
||
Data Reporting
|
||||
Final
form of data
|
hardcopy tables
electronic other |
|
||
Are
data publicly available?
|
Yes No |
On
the Internet?
Yes___ No___
|
||
Are
ancillary data available for samples?
|
temperature
salinity/conductivity
dissolved oxygen
hydrology/flow
others |
|
||
1 = Federal Geographic Data Committee http://www.fgdc.gov/metadata/